CT 36 / CT 48 Maintenance
wc_tx000374gb.fm 51
4.13 Trowel Lubrication
See Graphic: wc_gr001755
Grease trowel arms (b) with Shell Alvania RL2 grease or equivalent.
Oil the pitch control cable and other parts of trowel on an as needed
basis.
Oil in the gearbox should not require replacement unless it was
drained to service gearbox. Check quantity through plug (a) located on
side of gearbox. Oil level should be to bottom of the plug threads. See
Technical Data for oil quantity and type.
4.14 Optional Weights
To install optional weights, place equal number of weights in both front
and rear of guard ring in designated area. Tighten screw to keep
weights in place.
Under no circumstances should any object be used as additional
weight other than the weights recommended by Wacker. The use of
unauthorized weights could lead to personal injury or machine
damage.