wc_tx000551gb.fm 56
5. Guide Handle
5.1 Replacing the Throttle Cable
See Graphic: wc_gr003362
Disassembly:
5.1.1 Remove the engine air cleaner (d) if necessary to gain access to the
throttle cable at the engine. Unclamp the throttle cable from the throttle
casing clamp (g).
5.1.2 Disconnect the throttle cable (e) from the engine throttle bracket (f).
5.1.3 Pull the throttle cable through the cable guide (c) of the handle.
5.1.4 Remove the cable ties (a) from the handle.
5.1.5 Remove the screw and the casing fastener from the throttle control
lever (b) and remove the throttle cable from the machine.
Assembly:
5.1.6 Place the engine’s throttle control lever in the idle position. Connect the
throttle cable (e) to the engine throttle bracket (f) by placing the Z-bend
at the end of the cable through the hole in the throttle plate.
5.1.7 Using the throttle casing clamp (g) secure the throttle cable to the
engine.
5.1.8 Push the opposite side of the throttle cable through the cable guide (c)
of the handle.
5.1.9 Secure the throttle cable to the throttle control lever (b) and adjust it as
needed. See section Adjusting the Throttle Lever.
5.1.10 Secure the throttle cable to the handle with new cable ties (a).

Table of Contents

Other manuals for Wacker Neuson CT 48

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson CT 48 and is the answer not in the manual?

Wacker Neuson CT 48 Specifications

General IconGeneral
BrandWacker Neuson
ModelCT 48
CategoryTrowels
LanguageEnglish

Related product manuals