EasyManua.ls Logo

WAGNER GM 5000EA - The WAGNER Electrostatic Air Spraying System

WAGNER GM 5000EA
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
31
GM 5000EA
B_03266
OPERATING MANUAL
EDITION 04/2016 ORDER NUMBER DOC2344499
5.6 THE WAGNER ELECTROSTATIC AIR SPRAYING SYSTEM
The nozzle range (chapter 13) provided by WAGNER allows optimum coating results for
any application.
General criteria for selection of nozzles
Flat jet
for large-surface parts
Round jet for smaller delicate parts
Options for in uencing the jet spray / spray pattern:
Description Modi cation
Product pressure
+ or -
Atomizing air pressure + or -
Air regulation from open to closed
Stop screw product valve
from open to closed
Nozzle sizes Flow rate
Electrostatics + or - or o
5.6.1 PRESSURE SETTINGS FOR ROUND JET NOZZLES
Air regulation
closed
Air regulation
opened
There are 4 nozzle sizes, D8, D12, EARV LV and EARV HV available. The air cap and nozzle are
adjusted according to size to each other and may not be exchanged. During the calibration
of the product pressure
and the atomizing air pressure, the air control lever must
be in a central position as shown in the photo.
Pressure setting Nozzle D8 (small) Nozzle D12 (large) / EARV
Product pressure 0.8 bar to 1.2 bar 0.8 bar to 1.6 bar
Atomizing air pressure
2.0 bar to 2.3 bar 2.3 bar to 3.0 bar
The table contains default values. Depending on the product, conditions and the desired
result di erent values are possible or necessary.