58
GM 5000EA
OPERATING MANUAL
EDITION 04/2016 ORDER NUMBER DOC2344499
DANGER
Incorrect maintenance/repair!
Danger to life and equipment damage.
Only a WAGNER service center or a suitably trained person may
carry out repairs and replace parts.
Only repair and replace parts that are listed in the "Spare parts"
chapter and that are assigned to the unit.
Before all work on the device and in the event of work
interruptions:
- Switch o the energy supply and the compressed air supply.
- Relieve the pressure from the spray gun and device.
- Secure the spray gun against actuation.
Observe the operating and service manual for all work.
For the safe operation of electrostatic manual coating systems for  ammable liquid coating products,
intervals for periodical inspections are de ned as follows:
Inspection point Inspection interval Remarks
Gun cleaning, gun  ushing daily Chapter 4.2.4, Chapter 8.1
Hoses, tubes, couplings daily Chapter 8.2.4
Grounding weekly Chapter 4.2.2, Chapter 6.5.5
Inspection for damage weekly Chapter 8.1.3, 8.2, 10
Locking of the technical ventilation with the
electrostatic manual spraying unit
annually Chapter 6.5.2
The above recommended intervals are maximum values and may be modi ed by the operator depending on
the local and operational conditions and the contamination.
Damaged devices must be decommissioned and repaired immediately.
8.2.3 SAFETY CHECKS