7.3.5 CHANGING FROM AIR ROUND JET TO AIR FLAT JET
Defective electrode!
Material damage due to functional faults.
Do not damage the electrode.
NOTICE
Flush spray gun
1. Switch o control unit.
2. Relieve pressure.
Chapter 7.3.4
3. Connect the system to the
ushing agent supply.
4. Set product pressure. Close
atomizing air regulator.
5. Thoroughly  ush out the
spray gun.
6. Relieve pressure.
Chapter 7.3.4
Changing from round jet to  at jet
7. Unscrew the union nut (2) by hand.
8. Remove AR 5000 air cap (3). Unscrew AR 5000 nozzle (4)
by hand and remove it.
9. Clean the spray gun front carefully with damp cloth. Pay
attention to the electrode (1). Use the protection cap for
the valve needle (8).
10. Screw in and slightly tighten AF 5000  at jet nozzle (6) by hand.
11. Put the AF 5000 air cap (5) in place. Screw the union nut (2) onto the spray gun
body.
12. Set the desired  at jet level with the air cap horns (7) and then slightly tighten the
union nut by hand.
Changing from  at jet to round jet
7. Unscrew the union nut (2) by hand.
8. Remove AF 5000 air cap (5).
9. Unscrew and remove AF 5000  at jet nozzle (6) by hand.
10. Clean the spray gun front carefully with damp cloth. Pay attention to the
electrode(1). Use the protection cap for the valve needle (8).
11. Screw on and slightly tighten AR 5000 nozzle (4) by hand.
12. Position AR 5000 air cap (3). Screw the union nut (2) onto the spray gun body and
slightly tighten by hand.