MALFUNCTION POSSIBLE CAUSE ELIMINATION
Mortar spraying machine not
running.
Green operating light lights up
Delivery volume controller is set to „0“
Compressed air hose not connected or
inadequate compressed air supply
Air lter dirty (if tted)
Increase delivery volume
Check the compressed air hose and compressed
air supply
Clean the air lter
Mortar spraying machine not
running.
Green operating light does not
light up
Power supply missing.
- Plug in the power plug.
- Check the power cable for damage and replace,
if necessary.
- Check the power supply.
Mortar spraying machine not
running.
Red indicator light lights up (the
number of ashes represents an
error code)
Flash 3 times: Overcurrent
Flash 4 times: Over voltage
Flash 5 times: Under voltage
Flash 6 times: Communication inter-
ruption
Flash 7 times: Overheated
Flash 8 times: Locked
Continuous Flash with no stop: Com-
munication interruption
- Check if the rotor/stator, gearbox or feeder shaft
are stuck
- Check power supply voltage
- Check power supply voltage
- Unlock the emergency stop switch and restart
the machine. If the problem is not solved after
performing it three times, please contact Wagner
service or our designated distributors.
- Shutdown the machine and check if the motor
fan is faulty. If the fan is normal, wait until the con-
troller has cooled down. Try to start the machine
again.
- If after switching on the machine three times it is
still locked, please contact Wagner service or our
designated distributors.
- Please contact Wagner service or our designated
distributors.
Mortar spraying machine can-
not rotate the rotor
Rotor stuck in stator.
Pump was not lubricated with pump
sliding means.
Set the selector switch alternatively briey to “F”
(forwards) – “R (reverse).
Contact Wagner customer service if the problem
cannot be resolved.
Mortar spraying machine builds
up pressure in the mortar hose.
However, coating material does
not arrive at the spray lance.
Coating material "plug" in the mortar
hose. Mortar hose not prerinsed with
cellulose paste.
Depressurize the mortar hose – set the selector
switch to “R” (reverse).
Pump the coating material back into the contai-
ner.
The mortar hose must be pres-
sureless.
Watch the manometer ––> 0 bar.
Wear safety goggles.
Decouple mortar hose and rinse with water hose.
When the plug has been removed, ll cellulose
paste in the mortar hose. Couple the mortar hose
back on.
10 ELIMINATING FAULTS