EasyManuals Logo

WAGNER PEM-X1 CG User Manual

WAGNER PEM-X1 CG
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
37
VERSION 05/2019
ORDER NUMBER DOC2326960
PEM-X1 CG
8.2.2 MAINTENANCE INSTRUCTIONS
DANGER
Incorrect maintenance/repair!
Danger to life and equipment damage.
Only a WAGNER service center or a suitably trained person may carry out repairs and
replace parts.
Only repair and replace parts that are listed in the "Spare parts" chapter and that are
assigned to the unit.
Before all work on the device and in the event of work interruptions:
– Switch o the energy and compressed air supply.
– Relieve spray gun and device pressure.
– Secure the spray gun against actuation.
Observe the operating and service manual for all work.
Prior to maintenance
Flush and clean the system. Chapter 8.1.2
After maintenance
Carry out safety checks in accordance with Chapter 8.2.3.
Put the system into operation and check for leaks.
Have the system checked for safe condition by a skilled person.
8.2.3 SAFETY CHECKS AND MAINTENANCE INTERVALS
Daily: Before starting work, carry out a visual inspection to ensure that the system is grounded.
8.2.4 MAINTENANCE PROCEDURES
The maintenance intervals should be adapted by the operator depending on the level of
use and if necessary the level of soiling.
If in doubt, we recommend contacting WAGNER's specialist personnel.
Maintenance work Time stamp
once each shift weekly
Blow out gun and check for sintering
Check gun settings
Check gun discharge pressure
Blow out powder hoses
Check grounding
Check compressed air quality
Check gun voltage
Check powder hoses for bends and sintering

Table of Contents

Other manuals for WAGNER PEM-X1 CG

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGNER PEM-X1 CG and is the answer not in the manual?

WAGNER PEM-X1 CG Specifications

General IconGeneral
BrandWAGNER
ModelPEM-X1 CG
CategoryPower Tool
LanguageEnglish

Related product manuals