8.11 REPLACING THE CONNECTING TUBE
The connecting tube can be replaced if worn (for order number, see Chapter 13.6).
1. Remove the powder cup from the gun.
1.
2.
3.
4.
1
2
3
1
2
P_01736
3
Unscrew screws 1 and remove connecting part 2 from
gun body.
2. Unscrew connecting tube 3 from gun body.
3. Screw new connecting tube 3 into gun body.
4. Attach connecting part 2 to gun body and fasten with screws 1
(torque 40±10 Ncm).