PEM-X1 CG
11 DISASSEMBLY AND DISPOSAL
11.1 DISASSEMBLY
WARNING
Incorrect disassembly!
Risk of injury and damage to the device.
Before starting disassembly:
– Switch o the energy and compressed air supply.
– Ensure that all system components are grounded.
– Secure system against being switched back on without authorization.
Observe the operating manuals when carrying out all work.
Procedure:
1. Switch o the system.
2. Lock the compressed air supply and decompress system.
3. Disconnect the gun connection cable from control unit.
4. Disconnect the hose for feed air, dosing air and atomizing air from the spray gun
and from the control unit.
11.2 DISPOSAL
NOTICE
Do not dispose of used electrical equipment with household
refuse!
In accordance with European Directive 2012/19/EU on the disposal
of used electrical equipment and its implementation in national law,
this product may not be disposed of with the household refuse, but
must be recycled in an environmentally correct manner.
WAGNER or one of our dealers will take back your used WAGNER
electric or electronic equipment and will dispose of it for you in an
environmentally-friendly way. To arrange this, please contact one of
our service centers, one of our representatives or us directly.

Table of Contents

Other manuals for WAGNER PEM-X1 CG

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGNER PEM-X1 CG and is the answer not in the manual?

WAGNER PEM-X1 CG Specifications

General IconGeneral
BrandWAGNER
ModelPEM-X1 CG
CategoryPower Tool
LanguageEnglish

Related product manuals