46
VERSION 05/2019
ORDER NUMBER DOC2326960
PEM-X1 CG
Procedure:
5. Before inserting the electrode holder, the spring contact of
the gun body and contact surface of the electrode holder
should be checked.
P_01690
8.
7.
9.
6.
The spring contact must be clean and smooth-running, the
gun body must also be clean and free of powder deposits.
6. Insert electrode holder into gun housing.
7. Slide union nut onto gun housing.
8. Screw union nut onto gun housing (hand-tight).
9. Slide deector cone over deector cone sleeve.