45
ProfiTech M
OPERATING MANUAL
VERSION 07/2014 ORDER NUMBER DOC 2335144
X20 terminal block for powder center signal including EMERGENCY STOP
Function Signal Terminal strip Clamps Contact /Signal type
EMERGENCY STOP from
Powder Center
Channel 1 X20 1 and 2 Potential-free NCC
EMERGENCY STOP from
Powder Center
Channel 2 X20 3 and 4 Potential-free NCC
EMERGENCY STOP
transmission to PC
Channel 1 X20 5 and 6 Potential-free NOC
EMERGENCY STOP
transmission to PC
Channel 2 X20 7 and 8 Potential-free NOC
Outgoing air OK for Powder
Center
Contact X20 9 and 10 Potential-free NOC
Auxiliary voltage for inputs +24 VDC X20 11 +24 VDC from I/O Module
Powder center OK Digital IN X20 12 Digital input 24VDC/3.3 mA
Request PC cleaning Digital IN X20 13 Digital input 24VDC/3.3 mA
Start PC inside cleaning Digital IN X20 14 Digital input 24VDC/3.3 mA
Cleaning ready at PC Digital OUT X20 15 Digital output 24VDC/100 mA
Cleaning preparation PC Digital OUT X20 16 Digital output 24VDC/100 mA
GND for inputs and outputs GND X20 17 GND
X21 terminal block for booth control cabinet
Function Signal Terminal strip Clamps Contact /Signal type
Fire alarm Channel 1 X21 1 and 2 Potential-free NCC
Fire alarm Channel 2 X21 3 and 4 Potential-free NCC
EMERGENCY STOP
transmission to booth
control cabinet
Channel 1 X21 5 and 6 Potential-free NOC
EMERGENCY STOP
transmission to booth
control cabinet
Channel 2 X21 7 and 8 Potential-free NOC
Outgoing air OK for EPG S2 Contact X21 9 and 10 Potential-free NOC
Outgoing air OK for Powder
Center
Contact X21 11 and 12 Potential-free NOC
Ventilator 1 START/STOP Digital OUT X21 13 Digital output 24VDC/100 mA
Ventilator 2 (20 Hz Eco) Digital OUT X21 14 Digital output 24VDC/100 mA
Ventilator 3 (40 Hz normal) Digital OUT X21 15 Digital output 24VDC/100 mA
Booth light ON/OFF Digital OUT X21 16 Digital output 24VDC/100 mA
Booth cleaning ON/OFF Digital OUT X21 17 Digital output 24VDC/100 mA
Ventilator is running Digital IN X21 18 Digital input 24VDC/3.3 mA
Outgoing air OK
24 VDC Signal
Digital IN X21 19 Digital input 24VDC/3.3 mA
GND for inputs and outputs GND X21 20 GND