46
ProfiTech M
OPERATING MANUAL
VERSION 07/2014 ORDER NUMBER DOC 2335144
X30 terminal block for motion technique and EPG-S2 supply
Function Signal Terminal strip Clamps Contact /Signal type
Motion group 1 DC+ +24 VDC X30 1 +24 VDC fuse 1.6AT FS2
Motion group 1 DC_GND GND X30 2 GND
Motion group 1 AC 230 VAC X30 3 Phase fuse C25A F3A
Motion group 1 AC Neutral X30 4 Neutral conductor
Motion group 1 AC Earth X30 5 Grounding connection
Motion group 2 DC+ +24 VDC X30 6 +24 VDC fuse 1.6 AT FS2
Motion group 2 DC_GND GND X30 7 GND
Motion group 2 AC 230 VAC X30 8 Phase fuse C25A F3B
Motion group 2 AC Neutral X30 9 Neutral conductor
Motion group 2 AC Earth X30 10 Grounding connection
EPG group 1 AC Earth X30 11 Grounding connection
EPG group 1 AC 230 VAC X30 12 Phase D10A F2A Q3/1
EPG group 1 AC Neutral X30 13 Neutral conductor
EPG group 2 AC Earth X30 14 Grounding connection
EPG group 2 AC 230 VAC X30 15 Phase D10A F2B Q3/2
EPG group 2 AC Neutral X30 16 Neutral conductor
A maximum of two reciprocators and two sliding tables can be connected to a motion group.
This group's supply is controlled by the security switching device.
A maximum of 10 EPG-S2/EPG-Sprint X can be connected to an EPG group.
This group's supply is controlled by the K3 protection.