Machine Maintenance and Setup Menu
After a few cuts, you are very familiar with the cutting menu. Now it is time to familiar yourself with the menus that are built
into the Maintenance & Setup menu on your WAZER Pro.
Maintenance
Used Abr. Collect: This function turns on the Low Pressure system of WAZER Pro to collect Used Abrasive.
Nozzle Purge: This function turns on the High pressure system of WAZER Pro several times. It can be used to observe the
water stream and pressure for troubleshooting. Follow the instruction shown on UI screen.
Abr. Flow Rate:
This function turns on the abrasive system for 60 seconds to help the user measure the abrasive flow rate.
Refer to Online Support section for more information.
Tank Cleaning:
This function engages the High Pressure and Gantry systems to strategically stir used abrasive sediment
at the bottom of your tank. It will also turn on Low pressure system to collect used abrasive from tank bottom. Follow the
instruction shown on UI screen.
Water Level Setup: This function engages the High Pressure system and dump system to rise/lower water level to be within
operational range. Follow the instruction shown on UI screen.
Input/output check
Inpu
Door Switch: Follow the instructions on the screen to ensure the proper function of door switches interlock system.
Water Level Sensor:
Follow the instructions on the screen to ensure the proper function of water level sensors.
Service Sensor: Follow the instructions on the screen to ensure the proper function of the backflow sensor.
SD card: Follow the instructions on the screen to ensure SD card reader is able to register an inserted SD card.
Limit Switch: Follow the instruction on the screen to ensure the proper function of gantry and limit switches for your X and Y
axis.
Oupu
LP Pump: This function engages the Low Pressure Pump for a short time. You may hear a light humming noise as well as see
water being circulated in your tank.
Dump Valve: This function engages the Dump valve for a short time. You may hear a clicking sound being emitted from the
Right Side Cavity area, once to open the valve and once to close it. Follow the instruction shown on UI screen
Vibration Motors: This function engages vibration motors for a short time. You can discern a constant buzzing sound from
the Abrasive Hopper.
Abrasive Valve:
This function engages the Abrasive Valve for a short time. You may hear two clicking sounds being emitted
from the Right Side Cavity area, once to open the valve and once to close it
Clutch:
This function engages the High Pressure Pump Clutch for a short time. You may hear two soft click sounds from the
Pump section. If Clutch is not in good condition, you will hear squeakingn noise and see Operation Pressure dropping.
HP Pump: This function engages the AC motor in the Pump section for a short time. You may hear AC motor running in the
Pump Section powering up and down.
Jog:
This feature enables you to move the nozzle to any point on the Cut Bed by manually controlling the buttons on control
pad.