5
DETAILED PARAMETER DESCRIPTION
P0721 - Analog input AI5 function
Adjustable range: 0 to 0 Factory setting: 0
Acesso: Menu → Configurations → I/O → Analog inputs
Description:
When the option 0 (P0221/P0222) is selected, AI5 is able to provided the (if programmed so in P0221/P0222),
subject to the reference limits (P0133, P0134) and the ramp action (P0100 to P0103).
See Figure 5.24 on page 5-40.
Table 5.69: Analog input AI5 function
P0721 Function
0
P221/P222
✓
NOTE!
This parameter can be changed only with the motor stopped.
P0722 - Analog input AI5 gain (bipolar isolated MVC4 board)
Adjustable range: 0.000 to 9.999 Factory setting: 1.000
Acesso: Menu → Configurations → I/O → Analog inputs
Description:
Refer to P0234 (Analog input AI1 gain (unipolar MVC4 board)).
P0723 - Analog input AI5 signal type
Adjustable range: 0 to 3 Factory setting: 0
Acesso: Menu → Configurations → I/O → Analog inputs
Description:
For options 2 and 3 inverse reference is attained, that is, maximum speed is obtained with minimum reference.
When current signals are used at AI5 input, put S3.1 switch on the MVC4 control card in “ON” position.
Table 5.70: Analog input AI5 signal type
P0723 Function
0
0-10V/20mA
1
4 - 20 mA
2
10V/20mA-0
3
20 - 4 mA
✓
NOTE!
This parameter can be changed only with the motor stopped.
P0724 - Analog input AI5 offset (bipolar isolated MVC4 board)
Adjustable range: 0.0 to 100.0 % Factory setting: 0.0 %
Acesso: Menu → Configurations → I/O → Analog inputs
MVW3000 | 5-95