上海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD.
118 / 144
Wiring diagram in single Y configuration differs from that in double Y configuration
in that:
• X-axis, Y-axis and Z-axis servo interfaces should be connected to axis servo
interfaces 1, 2 and 4.
• Port X08 is the origin of Y-axis and port X09 is general input port.
Wiring Diagram of EX30A Terminal Board
Wiring diagram of EX30A terminal board is as follows:
Among the ports:
• The outputs of EX30A terminal board are Darlington outputs and their load
current cannot be more than 0.4A.
• Outputs Y00~Y05 should be conneted to relays.
• In configuration with follow-up, Y02 is set as Blow (Air).
• In configuration without follow-up, Y02 is set as Follow Control Switching.