3 Machine Tool Commissioning
This section mainly introduces how to do commissioning for the machine tool.
Before commissioning, click System Configs and select the proper configuration.
The machine tool commissioning includes the following:
Modify port polarity
Set drive parameters
Adjust pulse equivalent and electronic gear ratio
Set speed parameters
Adjust the axis direction
Set the workbench stroke
Compensate lead screw errors
Set parameters of air pressure and laser device
After commissioning, you need to check machine tool setting.
3.1 Modify Port Polarity
This operation is used to modify the polarity of a port, so as to make the port
effective.
Relationship between the status of the machine tool and IO ports is as follows:
Input port: means no signal; while means having a signal.
Output port: means no signal; while means having a signal.
To modify port polarity, do the following:
1. Click System Ports Setting. IO Ports dialog box pops up.
2. Click Convert Pol.
You can conduct or close a simulation test by clicking Test On or Test Off. The sign
T next to a port means the port is under testing.
3.2 Set Drive Parameters
This operation is used to run the machine tool according to your need.
Drive parameters differ in the follow-up control mode:
Drive parameters (in position loop control mode)
Drive parameters (in velocity loop control mode)
To set the target parameter to the setting value in parameter description, see user
manual of each brand for details.