6. Click . The system automatically does the following:
Save the information into screw error compensation file as a DAT file
with filename axeserr under directory C:\Program
Files\Weihong\NcEditor\config.
Compensate comprehensive errors according to the data in the file.
Restart the software to make the compensation effective.
3.8 Set Parameters of Air Pressure and Laser Device
To set parameters of air pressure and laser device, do the following:
1. To enter into General Parameters page in Layer Setting dialog box, do one of
the following:
In drawing toolbar, click General Parameters.
In menu bar, click Object Layer Setting General Parameters.
2. Set parameters in Pressure Control area and Laser Device Parameters area.