EasyManua.ls Logo

WEIHONG NcEditor V12 - Page 59

Default Icon
147 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
上海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD.
57 / 144
Parameters of air pressure and laser device are as follows:
Default Blow Type
The default gas for blowing.
If the selected gas is oxygen, port Proportioning Valve Enabled will be opened.
Default Blow P.
The pressure when the machine tool is in idle status.
Switch Gas Delay
Used for increment piercing and segment piercing.
The delay time for switching gas after piercing if the cutting gas is different from
that in piercing, with laser keeping on.
Gas on Delay
The delay time when port Blow is switched from off status to on status.
First Gas on Delay
Used to delay blowing for the start point.
Laser Device
Types of laser device.
If the selected laser device is SPI or IPG, the laser device will be turned on 5s before
the laser gate is turned on.
Port
The serial port for communication with the laser device.
The option None means the laser device is connected to the machine tool directly.
Modification of the parameter takes effect after the software is restarted.
Adjust Power Mode
Including Duty Ratio Adjust and Analog Adjust.
If Duty Ratio Adjust is selected, the speed power curve adjusts the duty ratio.
If Analog Adjust is selected, the speed power curve adjusts the peak power.
Laser Power
The power value when the laser power is 100%.

Other manuals for WEIHONG NcEditor V12