上海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD.
55 / 144
3. Click Load Tools. AxesErrorEditor dialog box pops up:
4. To import the RTL or LIN file, click File → Import File. The results include the
following:
– Values of parameters Position, Measured Value(Positive) and
Measured Value (Negative) show in the dialog box.
– Based on the above values, the system automatically calculates values of
parameters Positive Error, Negative Error, Backlash and Average
Backlash and fills into the dialog box.
– A compensation line chart shows in the dialog box:
• Red line represents errors in positive direction.
• Blue line represents errors in the negative direction.
5. Optional: Modify values of parameters Position, Measured Value(Positive)
and Measured Value (Negative). The results are the same with those in step 4.