72 / 144
4. Move upward the specified calibration distance after it touches the workpiece.
The system collects the calibration data and generates the calibration data:
Stability
The difference of the collected data between the segment of the cutting head
down 5mm before touching the workpiece and that of the cutting head up 5mm
after touching the workpiece.
The larger the difference is, the smaller the stability is.
If the stability is Bad, the fluctuation may be relatively more unstable or the
external interference may be relatively more serious. You need to calibrate
capacitance again.
Smooth
The smoothness of the curve.
If the smoothness is Bad, the curve is not flat with ups and downs or burrs. You
need to calibrate capacitance again.
Note: During calibrating capacitance, e-stop button is for use at any time in case of machine tool damage
caused by cutting head continuous moving downward if the capacitance for touching the workpiece is
incorrect.