1
WEILER E1250
3-8
Maintenance
3
HYDRAULIC PRESSURE
Ground Drive Pump- Front
Charge Presure 350psi See page 1-13 for location
System Pressure 350psi in Neutral See page 1-13 for locationl
6090psi Max
Ground Drive Pump- Rear
Charge Pressure 350psi See page 1-14 for location
System Pressure 350psi in Neutral See page 1-14 for location
6090psi Max
Elevator Pump
Charge Pressure 350psi See page 1-16 for location
System Pressure 350psi in Neutral See page 1-16 for location
6090psi Max
Conveyor Pump
Charge Pressure 350psi See page 1-16 for location
System Pressure 350psi in Neutral See page 1-16 for location
6090psi Max
Remix Hopper Pump(Optional)
Charge Pressure 300psi See page 1-18 for location
System Pressure 300psi in Neutral See page 1-18 for location
5000psi Max
Auxiliary Hydraulic System - Pressure Compensated
System Pressure 2800psi See page 1-19 for locationl