4 Installation
83252902 1/2019-09 La
26-84
4.4 Burner installation
Fit flange gasket 3 and hinged flange 2 to the boiler plate using screws 1.
The aperture between combustion head and refractory should be filled with
flame-proof, resilient insulating material. Do not make solid.
2
3
1
Using suitable lifting equipment lift burner and, using hinge pins1 fit into hinged
flange, observe pivoting direction.
Without combustion head extension
Close burner and secure with dome nut2.