General
Voltage
Voltage
Regulation
Frequency
Regulation
Rating
(Volts
AC)
60
Hertz
(1800
rpm)
8.0KW
50
Hertz
(1500
rpm)
6.0KW
Generator
Cooling
Air
Requirements
(60
Hertz)
at
1800
rpm
SPECIFICATIONS
WESTERBEKE
8.0
KW
BTD
GENERATOR
AC
GENERATOR
Brushless,
four-pole,
revolving
field.
Pre-lubricated,
single-bearing
design.
Reconnectable,
single-phase
transformer
regulation
(optional
solid
state
voltage
regulator)
120
or
1201240
Volts
-
60
Hertz
220
Volts
-
50
Hertz.
±5%
no
load
to
full
load.
±3
Hertz
(5%)
no
load
to
full
load.
120
Volts
66
Amps
120/240
Volts
66/33
Amps
220
Volts
27
Amps
175-200
cfm
(5.66-
6.37
cmm)
GENERATOR
COOliNG
Engine
Combustion
Air
Requirements
(60
Hertz
at
1800
RPM)
Generator
Compartment
Ambient
Temperature
Recommendations
Cooling
Air
32
cfm
(.906
cmm)
104"f
(40"C)
maximum
NOTE:
Forced
ventilanon
should
be
provided
to
mafntafn
gtJneratar
compartment
temptJra-
tures
below
104°F
(40°G).
100-200
ctm
(2.83-5.66
cmm)
NOTE:
Increase
air
supply
15%
tor
50
Hertz
operation
(1500
rpm).

Other manuals for Westerbeke 12.5 BTDA