PROCEDURE
1 Change over to the clean filter chamber.
2 Drain the clogged filter chamber.
3 Remove the cover of the clogged filter chamber.
4 Remove the filter element from the filter chamber.
5 Clean the filter chamber.
6 Clean the filter element or take a new filter element.
7 Install the new filter element into the filter chamber.
8 Install the cover on the filter chamber.
9 Make sure that the cleaned filter chamber has no leaks.
CLOSE UP
None
X92-B
AA00-7200-00AAA-200A-A
Operation Manual Replace the filter element of the duplex filter