4.2 Cooling water system
The cooling water system supplies the items that follow with cooling water:
Cylinder liner
Cylinder cover
Exhaust valve cages
Scavenge air cooler (SAC).
For the schematic diagrams, refer to section 13.1 Schematic diagrams - general.
The cooling water system has the engine connections as interface to the plant as follows (in Figure
4-2 marked with a circle):
Connection 01 (cylinder cooling water inlet)
Connection 02 (cylinder liner cooling water inlet (bypass cooling water system)) (optional)
Connection 03 (cylinder cooling water outlet)
Connection 05 (cylinder cooling water drain outlet)
Connection 07 (SAC LT-cooling water inlet) (not shown)
Connection 08 (SAC LT-cooling water outlet) (not shown).
If the supply at the engine connection 02 is installed, the cylinder liner is supplied with cooling
water at a higher temperature than the cylinder cover.
The cooling water system has the parts that follow:
Automatic venting unit
The automatic venting unit (001) constantly releases unwanted air from the cooling water.
Optional vent valve
The optional vent valves (008) can be used manually to release unwanted air from the
cooling water, if the automatic venting unit (001) does not operate correctly.
Vent valve
The vent valves (009) constantly release cooling water to the automatic venting unit (001)
to release unwanted air from the cooling water.
Vent valve
The vent valve (010) can be used manually to release unwanted air from the cooling water,
if the automatic venting unit (001) does not operate correctly.
X92-B
AA00-0000-00AAA-043A-A
Operation Manual Cooling water system
Winterthur Gas & Diesel Ltd.
- 70 - Issue 002 2021-11