EasyManua.ls Logo

WinGD X92-B - Page 329

WinGD X92-B
460 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10.2.5 Malfunctions of systems for DF engine (XX33NN to XX39NN)
Tab 10-34 Gas concentration in piston underside is too high
Indication Possible cause Procedure
AE3315C There is a leakage in the gas sys-
tem
Find the cause and repair the defective item.
Tab 10-35 Difference pressure of pilot fuel filter is too high
Indication Possible cause Procedure
PS3464A The pilot fuel filter is clogged
Replace the filter element.
Tab 10-36 Gas supply pressure is too low
Indication Possible cause Procedure
PT3901C The gas supply is defective
Find the cause and repair the fault.
The gas filter is clogged
Clean or replace the gas filter. For the filter
of the iGPR refer to [section not applicable
for this engine].
X92-B
AA00-0000-00AAA-410C-A
Operation Manual Malfunctions of systems and components
Winterthur Gas & Diesel Ltd.
- 329 - Issue 002 2021-11

Table of Contents

Related product manuals