PROCEDURE
1 Cut out the defective cylinder from the injection, refer to section 10.8 Temporary cut out a
defective injection valve.
2 Disconnect the electrical connection to the related exhaust valve control unit (VCU).
3 Repair the fault as soon as possible, refer to the Maintenance Manual.
CLOSE UP
The engine can be started and operated at decreased load, refer to section 8.3 Start the
engine - general
X92-B
AA00-0000-00AAA-662D-A
Operation Manual Temporary cut out a defective exhaust valve drive
Winterthur Gas & Diesel Ltd.
- 357 - Issue 002 2021-11