INDUCTION RANGE ERROR CODES
Error
Code
Shown Phrase PRI Component Error Description Service Instruction
1621 eAuxiliaryDLBOpen 2 Right oven The DLB relay on the
auxiliary outputs is open
when it should be closed.
1 Replace the relay board.
1622 eAuxiliaryDLBOpen 2 Left oven
1 Replace the relay board.
1731 eOvenLightDriveOpen 3 Right oven The drive circuit for the
oven light is open when it
should be conducting.
1 Check the light circuit.
2 Replace the relay board.
1732 eOvenLightDriveOpen 3 Left oven
1 Check the light circuit.
2 Replace the relay board.
1831 eMDLDriveOpen 3 Right oven The drive circuit for the
MDL is open when it
should be conducting.
1 Check the MDL circuit.
2 Replace the relay board.
1832 eMDLDriveOpen 3 Left oven
1 Check the MDL circuit.
2 Replace the relay board.
1931 eRConvFanDriveOpen 3 Right oven The drive circuit for the
convection fan is open
when it should be
conducting.
1 Check the right convection fan
circuit.
2 Replace the relay board.
1932 eRConvFanDriveOpen 3 Left oven
1 Check the right convection fan
circuit.
2 Replace the relay board.
1A31 eLConvFanDriveOpen 3 Right oven The drive circuit for the
convection fan is open
when it should be
conducting.
1 Check the left convection fan
circuit.
2 Replace the relay board.
1A32 eLConvFanDriveOpen 3 Left oven
1 Check the left convection fan
circuit.
2 Replace the relay board.
1B21 eCoolingFanDriveOpen 2 Right oven The drive circuit for the
cooling fan is open when
it should be conducting.
1 Check the cooling fan circuit.
2 Replace the relay board.
1B22 eCoolingFanDriveOpen 2 Left oven
1 Check the cooling fan circuit.
2 Replace the relay board.
2031 ePCMAmbientTempCircuitFault 3 Right oven The ambient temperature
sensor circuit on the relay
board is malfunctioning.
1 Replace the relay board.
2032 ePCMAmbientTempCircuitFault 3 Left oven
1 Replace the relay board.
2131 ePCMNotCalibrated 3 Right oven The relay board
calibration data is blank
or corrupted.
1 Replace the relay board.
2132 ePCMNotCalibrated 3 Left oven
1 Replace the relay board.
2421 eRTDCircuitFault 2 Right oven The RTD circuit on the
relay board is
malfunctioning.
1 Check the RTD circuit.
2 Replace the oven relay board.
2422 eRTDCircuitFault 2 Left oven
1 Check the RTD circuit.
2 Replace the relay board.
2521 eMDLSwitchCircuitFault 2 Right oven The MDL switch circuit on
the relay board is
malfunctioning.
1 Check the MDL circuit.
2 Replace the relay board.
30" and 36" Induction Range
Troubleshooting
Induction Range Error Codes