INDUCTION RANGE ERROR CODES
Error
Code
Shown Phrase PRI Component Error Description Service Instruction
2522 eMDLSwitchCircuitFault 2 Left oven
1 Check the MDL circuit.
2 Replace the relay board.
2631 eDoorSwitchCircuitFault 3 Right oven The door switch circuit on
the relay board is
malfunctioning.
1 Check the door switch circuit.
2 Replace the relay board.
2632 eDoorSwitchCircuitFault 3 Left oven
1 Check the door switch circuit.
2 Replace the relay board.
2931 eLineVoltageSenseCircuitFault 3 Right oven The incoming voltage
level detection circuit on
the relay board is
malfunctioning.
1 Replace the relay board.
2932 eLineVoltageSenseCircuitFault 3 Left oven
1 Replace the relay board.
2A31 eLVM_HVMCommunFault 2 Right oven No communications or
too many bad packets
between the two
processors on the relay
board.
1 Replace the relay board.
2A32 eLVM_HVMCommunFault 2 Left oven
1 Replace the relay board.
2B31 eHVMMonitorCircuitFault 3 Right oven One of the output monitor
circuits on the relay board
is malfunctioning.
1 Replace the relay board.
2B32 eHVMMonitorCircuitFault 3 Left oven
1 Replace the relay board.
2C21 ePCMRs485NetworkFault 2 Right oven The relay board detects
an error with the RS485
network.
1 Check the RS485 circuitry.
2 Replace the relay board.
2C22 ePCMRs485NetworkFault 2 Left oven
1 Check the RS485 circuitry.
2 Replace the relay board.
3031 eTemperatureProbeShorted 3 Right oven The temperature probe is
broken. The socket is
broken or wired wrong.
Probe circuit reporting
below 1k Ω.
1 Check the probe circuitry.
2 Replace the relay board.
3032 eTemperatureProbeShorted 3 Left oven
1 Check the probe circuitry.
2 Replace the relay board.
3121 eRTDShorted 2 Right oven The RTD is broken or
wired wrong. RTD circuit
reporting below 825 Ω.
1 Check the RTD circuit.
2 Replace the relay board.
3122 eRTDShorted 2 Left oven
1 Check the RTD circuit.
2 Replace the relay board.
3221 eRTDOpen 2 Right oven The RTD is broken or
wired wrong. RTD circuit
reporting below 3049 Ω.
1 Check the RTD circuit.
2 Replace the relay board.
3222 eRTDOpen 2 Left oven
1 Check the RTD circuit.
2 Replace the relay board.
3311 eTCOOpen 1 Right oven The TCO has opened due
to excessive temperature
or a wiring issue.
1 Check the TCO circuit.
2 Replace the TCO.
3312 eTCOOpen 1 Left oven
1 Check the TCO circuit.
2 Replace oven TCO.
4021 eBakeElementLoadMissing 2 No load detected when
the element is turned on.
1 Check the bake element.