INDUCTION COOKTOP ERROR CODES
INDUCTION ERROR CODES
Error
Code
Error Component Error Description Service Instruction
E 00 Overvoltage Generator
Over voltage detection from the
induction generator.
1 Check voltage supply.
2 Replace induction generator.
E 01 Left key error Left secondary
Key error on the left secondary
1 Reseat wire harnesses.
2 Replace the left secondary control
board.
E 02 Right key error Right secondary
Key error on the right secondary
1 Reseat wire harnesses.
2 Replace the right secondary control
board.
E 03 Center key error Primary
Key error on the primary
1 Reseat wire harnesses.
2 Replace the primary control board.
E 04 Data flash error All components
Not a shown error. A cyclic reset
of the controller
1 Cycle the unit electrical supply.
2 Replace the primary and secondary
control boards.
3 Replace the induction generator.
E 05 LIN communication error Primary
No response from the generator.
Cable or generator issue.
1 Reseat the wire harnesses.
2 Replace the induction generator.
E 06 Controller options error
Not currently used
E 07 TC temperature too high Primary
Primary is too hot.
1 Check airflow for blockage.
2 Replace primary control board.
E 08
Invalid generator
configuration
Generator
1 Cycle the unit electrical supply.
2 Replace the induction generator.
E 09
Coil assembly 1 temperature
too high
Generator
1 Replace the coil assembly.
2 Replace the induction generator.
E 10
Coil assembly 2 temperature
too high
Generator
1 Replace the coil assembly.
2 Replace the induction generator.
E 11
Coil assembly 3 temperature
too high
Generator
1 Replace the coil assembly.
2 Replace the induction generator.
E 12
Coil assembly 4 temperature
too high
Generator
1 Replace the coil assembly.
2 Replace the induction generator.
E 13
Coil assembly 5 temperature
too high
Generator
1 Replace the coil assembly.
2 Replace the induction generator.
E 14 Configuration implausible Generator
• 0x13 = CRC error of
configuration data.
• 0x30 = Configuration values
implausible.
1 Cycle the unit electrical supply.
2 Replace the induction generator.
E 15
Power supply error on
generator
Generator
Generator voltage too low.
1 Check voltage supply.
2 Replace induction generator.
30" and 36" Induction Range
Troubleshooting
service.subzero.com
829191 REVA
75