INDUCTION ERROR CODES
Error
Code
Error Component Error Description Service Instruction
E 16 Unspecified generator error Generator
1 Cycle the unit electrical supply.
2 Replace the induction generator.
E 17 Unspecified primary error Primary
1 Cycle the unit electrical supply.
2 Replace the primary control board.
E 18
Unspecified left secondary
error
Left secondary
1 Cycle the unit electrical supply.
2 Replace the left secondary control
board.
E 19
Unspecified right secondary
error
Right secondary
1 Cycle the unit electrical supply.
2 Replace the right secondary control
board.
E 20
Temperature monitoring
error
Generator
0x27 = Heat sink sensor
failure.
0x36 = Temperature pin
short cut.
0x41 = Zone temperature
value invalid.
1 Cycle the unit electrical supply.
2 Replace the induction generator.
E 21 Controller error
Primary
Left secondary
Right secondary
Not a shown error. A cyclic reset
of the controller
1 Cycle the unit electrical supply.
2 Replace the primary and secondary
control boards.
3 Replace the induction generator.
E 30 Generator relay error Generator
1 Cycle the unit electrical supply.
2 Replace the induction generator.
E 31
Not valid as of V0.15 - See:
E 39
E 40
E 41
E 42
E 43
E 32 Invalid potentiometer Generator
1 Cycle the unit electrical supply.
2 Replace the induction generator.
E 33 Coil temperature sensor Generator
Two wire connection from the
coil NTC to the generator is not
connected correctly or bad.
1 Check the NTC connection to the
generator.
2 Replace the coil.
E 34 Fan 1 error Generator
Fan speed implausible
1 Check for obstructions.
2 Replace the fan assembly.
3 Replace the induction generator.
E 35 Fan 2 error Generator
Fan speed implausible
1 Check for obstructions.
2 Replace the fan assembly.
3 Replace the induction generator.
E 36 Fan 3 error Generator
Fan speed implausible
1 Check for obstructions.
2 Replace the fan assembly.
3 Replace the induction generator.
30" and 36" Induction Range
Troubleshooting
Induction Cooktop Error Codes