INDUCTION ERROR CODES
Error
Code
Error Component Error Description Service Instruction
E 37 Fan 4 error Generator
Fan speed implausible
1 Check for obstructions.
2 Replace the fan assembly.
3 Replace the induction generator.
E 38 Fan 5 error Generator
Fan speed implausible
1 Check for obstructions.
2 Replace the fan assembly.
3 Replace the induction generator.
E 39 Generator hardware Generator
• 0x32 = ADC error.
• 0x50 = ADC error.
1 Cycle the unit electrical supply.
2 Replace the induction generator.
E 40 Generator hardware Generator
• 0x33 = Sync error.
1 Cycle the unit electrical supply.
2 Replace the induction generator.
E 41 Generator hardware Generator
• 0x23 = PWM output error.
1 Cycle the unit electrical supply.
2 Replace the induction generator.
E 42 Generator hardware Generator
• 0x20 = cyclic reset of
generator - E05.
1 Cycle the unit electrical supply.
2 Replace the induction generator.
E 43 Generator hardware Generator
• 0x39 = cyclic reset of
generator - E05.
1 Cycle the unit electrical supply.
2 Replace the induction generator.
E 44 Not currently in use.
E 45 LIN hardware error Primary
LIN - Hardware on primary is
broken.
1 Replace the primary control board.
E 46 RS485 hardware error Primary
Not a shown error. Only logged
for the options menu.
1 Cycle the unit electrical supply.
2 Replace the primary control board.
E 47
Power supply error on
primary
Primary
Voltage regulator on the primary
broken.
1 Replace the primary control board.
E 48
Power supply error on left
secondary
Left secondary
Voltage regulator on the left
secondary is broken.
1 Replace the left secondary control
board.
E 49
Power supply error on right
secondary
Right secondary
Voltage regulator on the right
secondary is broken.
1 Replace the right secondary control
board.
E 50
Continuous key push on the
primary
Primary
This error is not logged or
shown. The board slider blinks.
1 Reseat the wire connectors.
2 Replace the primary control board.
E 51
Continuous key push on the
left secondary
Left secondary
This error is not logged or
shown. The board slider blinks.
1 Reseat the wire connectors.
2 Replace the left secondary control
board.
E 52
Continuous key push on the
right secondary
Right secondary
This error is not logged or
shown. The board slider blinks.
1 Reseat the wire connectors.
2 Replace the right secondary control
board.
E 53
Left secondary defect or
wire harness broken
Left secondary
No communication with the left
secondary control board
possible.
1 Inspect the wire harness.
2 Replace the left secondary control
board.
E 54
Right secondary defect or
wire harness broken
Right secondary
No communication with the
right secondary control board
possible.
1 Inspect the wire harness.
30" and 36" Induction Range
Troubleshooting
Induction Cooktop Error Codes
service.subzero.com
829191 REVA
77