INDUCTION ERROR CODES
Error
Code
Error Component Error Description Service Instruction
2 Replace the right secondary control
board.
E 55
Primary communication
error
Primary
Possible communication
hardware error on the primary or
bus short cut. Communication
with the secondaries is not
possible.
1 Inspect the wire harness.
2 Replace the primary control board.
E 56
Left secondary temperature
too high
Left secondary
Left secondary is too hot.
1 Replace the left secondary control
board.
E 57
Right secondary
temperature too high
Right secondary
Right secondary is too hot.
1 Replace the right secondary control
board.
E 58 Not currently in use.
E 59 Not currently in use.
E 60 Low voltage detected Primary
1 Check voltage supply.
2 Replace primary control board.
E 61 Hardware error primary Primary
NTC failure
1 Check the NTC circuit.
2 Replace the primary control board.
E 62
Hardware error left
secondary
Left secondary
NTC failure
1 Check the NTC circuit.
2 Replace the left secondary control
board.
E 63
Hardware error right
secondary Primary
Right secondary
NTC failure
1 Check the NTC circuit.
2 Replace the right secondary control
board.
E 64 Not currently in use.
30" and 36" Induction Range
Troubleshooting
service.subzero.com
829191 REVA
78