Rectifying faults
E9 and flashing.
Safety temperature limiter has tripped.
Check Action
1. Is the heating pressure between 1
and 2 bar?
yes: B Top up system.
B Vent appliance.
B Press , does appliance restart???
E9?2.
no: 2.
2. Is the pump blocked? yes: B Unblock the pump.
If pump won’t start:
B Power OFF the appliance.
B Disconnect the boiler electrical connection.
B Change the pump.
B Reconnect the boiler electrical connection.
B Turn ON the appliance.
B Press , does appliance restart???
E9? 3.
no: 3.
3. Is lead disconnected from one/both
safety temperature limiters?
yes: B Power OFF the appliance.
B Connect lead.
B Turn ON the appliance.
B Press , does appliance restart???
E9? 4.
no: 4.
4. B Power OFF the appliance.
B Unplug the connector from the
cut-off device.
B Measure the NTC electrical resist-
ance.
R = ?
yes: B Change the over heating cut-off device.
B Connect flue gas safety temperature limiter lead.
B Turn ON the appliance.
B Press , does appliance restart???
E9? 5.
no: B Connect flue gas safety temperature limiter lead.
B Turn ON the appliance.
E9? 5.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Worcester GREENSTAR HE combi Series and is the answer not in the manual?

Worcester GREENSTAR HE combi Series Specifications

General IconGeneral
BrandWorcester
ModelGREENSTAR HE combi Series
CategoryBoiler
LanguageEnglish

Related product manuals