7 181 465 347 (01.07)28
Rectifying faults
EA and flashing.
During operation: flame not detected
Check Action
1. Is the flame present? yes: ↓6.
no: ↓2.
2. Is the gas cock open? yes: ↓3.
no: B Open the gas cock
B Press , does appliance restart???
EA? ↓3.
3. Is there air in the supply pipe? yes: B Vent supply pipe.
B Press , does appliance restart???
EA? ↓4.
no: ↓4.
4. Did the thermical security of the gas
cock lock out?
yes: B Reset security.
B Press , does appliance restart???
EA? ↓5.
no: ↓5.
5. Natural gas models:
does the building have a supply pres-
sure regulator?
yes: B Check that it is fitted correctly and functioning
properly and correct if necessary.
B Check supply pressure, inform gas company if
outside correct range.
B Press , does appliance restart???
EA? ↓6.
no: ↓6.
LPG models:
is the flow rate of the gas supply to
the appliance correct?
yes: ↓6.
no: B Is there enough gas in the supply cylinder?
B Is there air in the supply pipe?
B Is the solenoid valve in the “meter cabinet” open-
ing?
B Is the supply pressure OK? (if the supply pres-
sure is too high, check the pressure regulator in
the “meter cabinet” and on the LPG supply cylin-
der).
B Press , does appliance restart???
EA? ↓6.