Rectifying faults
FA and flashing.
After appliance switches off flame is detected
Check Action
1. Is condensation trap in condensing
boiler blocked?
yes: B Clean condensation trap discharge pipe.
B Press , does appliance restart???
FA? 2.
no: 2.
2. Electrodes faulty. B Replace electrode assembly.
B Turn ON the appliance.
B Press , does appliance restart???
FA?
B Power OFF the appliance.
3.
3. Problem with flue?
B Check CO
2
level in combustion
air.
> 0,2 % CO
2
?
yes: B Check flue and repair or replace if necessary.
B Press , does appliance restart???
FA?
B Power OFF the appliance.
4.
no: 4.
4. The gas valve is damaged. B Change the gas valve.
B Turn ON the appliance.
B Press , does appliance restart???
FA?
B Power OFF the appliance.
5.
5. Check if the 20-pin connector lead
assembly is damaged.
B Change the 20-pin connector lead assembly.
B Turn ON the appliance.
B Press , does appliance restart???
FA?
B Power OFF the appliance.
6.
6. The PCB control board is damaged. B Disconnect the boiler electrical connection.
B Change PCB control board.
B Reconnect the boiler electrical connection.
B Turn ON the appliance.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Worcester GREENSTAR HE combi Series and is the answer not in the manual?

Worcester GREENSTAR HE combi Series Specifications

General IconGeneral
BrandWorcester
ModelGREENSTAR HE combi Series
CategoryBoiler
LanguageEnglish

Related product manuals