Troubleshooting Reference
78 Freedom XC Owner's Guide
Problem Possible Cause Solution
No output voltage is shown in the LCD
screen but the green status LED for
Battery mode is illuminated.
GFCI (when installed) has tripped
or supplementary breaker has
tripped.
Check load and reset the GFCI or supplementary
breaker.
Circuit breaker on the AC load
panel or AC output disconnect has
tripped.
Reset the circuit breaker or check the AC output
disconnect circuits.
Battery voltage is too low
(depending on setting, see
Maintaining the Freedom XC Unit
on page 70) to start inverting. LCD
screen may show DC voltage as
000.
Check DC connections and cable.
Recharge battery.
No output voltage is shown in the LCD
screen and neither of the green status
LEDs (for Grid mode and Battery mode)
is illuminated.
AC shore power is not available or
out of operating range and the
inverter/charger is OFF.
Check AC shore power.
Turn the inverter/charger ON.
AC shore power is not available
and the inverter/charger is OFF
due to a shutdown for more than
30 s.
Check AC shore power and battery voltage.
Turn the inverter/charger ON and look at the LCD
screen for any error code.
See "Error codes displayed on the LCD screen" on
page74.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex Freedom XC 2000 and is the answer not in the manual?

Xantrex Freedom XC 2000 Specifications

General IconGeneral
Continuous Power2000W
Surge Power4000W
Input Voltage12V DC
Output Voltage120V AC
Output Frequency60 Hz
WaveformPure Sine Wave
Efficiency90%
Operating Temperature-4°F to 140°F (-20°C to 60°C)
Transfer Time20ms