03
Internal position mode
-
n.0000
5
04
Effective segment number
1
1-35
5
10
First segment pulse (low
byte)
1 pulse
0
-9999~99
99
5
11
First segment pulse (high
byte)
10000
pulses
0
-32767~3
2767
5
12
First segment speed
0.1rpm
0
0~10000
5
13
First segment acceleration
time
1ms
0
0~65535
5
14
First segment deceleration
time
1ms
0
0~65535
5
15
Reserved
-
-
-
-
5
16
Adjustment time
1ms
0
0~65535
5
P4-17~P4-23 are internal position segment 2 parameters, the following total 35 segments.
Note: (1) setting pulse number = pulse numbers (high byte)×10000+pulse number(low byte)
(2) total 35 segments. Segment 1~12 parameters can be set through operate panel, segment
13~35 can write in parameters through communication (RS232 or RS485).
P5: signal parameter
P5-
Name
Unit
Default
Range
Effective
Suitable
mode
00
Positioning finished width
/COIN
Command
unit
7
0~
65535
6
01
Positioning finished checking
mode
0: offset absolute value below
P5-00, output COIN signal
-
0
0~3
6