EasyManuals Logo

Xinje DS5C Series User Manual

Xinje DS5C Series
121 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
97
decrease the
load
2. good
ventilation,
decrease
environment
temperature
3. check if the
fan works when
servo enabled,
module
temperature
U0-06≥45, fan
will work.
1
E-061
Motor
temperature too
high
1. long time running
with large load
2. environment
temperature too high
1. decrease the
load
2. good
ventilation
2
E-062
Drive too cold
1. Environment
temperature is too low
2. drive temperature
collection chip
The environment
must up to 0
07
0
E-070
Overcurrent
1.Driver U/V/W Output
Short Circuit
2. Motor failure
3. The load part is
blocked.
1. Replace the
damaged motor
and check the
UVW
connection of
the motor.
2. It is suggested
that the motor be