98
operated on an
empty shaft to
eliminate the
load problem.
08
0
E-080
Over speed
1. motor speed too fast
2. motor UVW
connection error
3. parameters error
1. check if there
is external force
make the motor
over speed
2. check UVW
wiring
3. actual speed
larger than
P3-21/P3-22 will
alarm
09
2
E-092
Analog Tref
Zero-Calibration
Overrun
Analog zero calibration
operation error
Please not add
analog value
when calibrating
3
E-093
Analog Vref
Zero-Calibration
Overrun
Analog zero calibration
operation error
Please not add
analog value
when calibrating
10
0
E-100
Position offset
too large
The difference between
setting position and
actual position is over
the limit
1. check whether
the motor stall,
decrease the
position setting
speed
2. increase the
offset pulse limit
P0-23
11
0
E-110
Motor UVW
1external short
1. check motor

Table of Contents