96
e
(220V:
U0-05
390 alarm,
380V:
U0-05
780V
alarm)
2. not connect
regenerative
resistor
3. regenerative
damaged or
resistor too large
2. connect regenerative
resistor
3. check if the
regenerative resistor
matched power
390 alarm,
380V: U0-05
780V alarm)
04
0
Bus
undervolta
ge(220V:
U0-05
140.
380V:
U0-05
300)
1. Power grid
voltage too low
2. instant power
off
1. check the grid
fluctuation
2. use constant voltage
source
Bus
undervoltage(22
0V: U0-05
140.
380V: U0-05
300)
1
Drive
power off
Drive power cut
off
Check the power
supply
Drive power off
3
Bus
voltage
charging
failure
Hardware
damage
Please note if there is
relay ON/OFF sound
when drive power on
Bus voltage
charging failure
06
0
E-060
Module
temperature too
high
1. long time running
with large load
2. environment
temperature too high
3. fan has error
1. consider
change the
motor
capacity(mointor
U0-02, motor
present torque)