95
out of
range
value out of
range
and set again
range
2
Parameter
conflict
TREF or VREF
function setting
conflict
1. P0-01=4, P3-00=1
will alarm
Parameter
conflict
3
Sampling
channel
setting
error
User-defined
output trigger
channel or data
monitor channel
setting error
Check the setting
parameter
Sampling
channel setting
error
4
Parameter
lost
Power supply
voltage too low
1.for single phase 220V,
connect L1, L3
2. set the parameter
again
Parameter lost
5
Erase flash
error
Parameter store
error when
power off
Contact us
Erase flash error
6
Initialize
flash error
Flash chip
power supply
not stable
Contact us
Initialize flash
error
02
8
E-028
Data Reading
Failure in
Communication
1. Poor cable contact or
disconnection 2.
Abnormal data
communication
between driver and
motor
1. Check
communication
wiring 2.
Re-energize and
power off
03
0
Bus
overvoltag
1. power grid
voltage too high
1. check the grid
fluctuation
Bus overvoltage
(220V: U0-05