68
com
mand
unit
35
24
Discharge resistance type
0: built in
1: external
-
0
0~1
All
25
Discharge Resistance power
W
Related
to
driver
power
0~655
35
All
26
Discharge Resistance value
Ω
0~655
35
All
27
Servo OFF Stop Mode
0: Inertial operation stops and
remains in inertial operation state
after stopping.
2: The deceleration operation stops,
and the inertia operation state is
maintained after the stop.
-
0
02
All
28
Servo Overrun Stop Mode
0: deceleration stop, after stop,
overrun direction moment is 0,
receive instructions.
1: Inertia stops, after stopping,
overrun direction moment is 0,
receiving instructions.
2: The deceleration stops, after
stopping, the overrun direction
does not receive instructions.
3: Alarm (E-260)
-
0
0~3
All
29
Servo Alarm Stop Mode
0: Inertial operation stops and
remains in inertial operation state
-
0
02
All