EasyManua.ls Logo

Xinje DS5C Series

Xinje DS5C Series
121 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
68
com
mand
unit
35
24
Discharge resistance type
0: built in
1: external
-
0
0~1
All
25
Discharge Resistance power
W
Related
to
driver
power
0~655
35
All
26
Discharge Resistance value
Ω
0~655
35
All
27
Servo OFF Stop Mode
0: Inertial operation stops and
remains in inertial operation state
after stopping.
2: The deceleration operation stops,
and the inertia operation state is
maintained after the stop.
-
0
02
All
28
Servo Overrun Stop Mode
0: deceleration stop, after stop,
overrun direction moment is 0,
receive instructions.
1: Inertia stops, after stopping,
overrun direction moment is 0,
receiving instructions.
2: The deceleration stops, after
stopping, the overrun direction
does not receive instructions.
3: Alarm (E-260)
-
0
0~3
All
29
Servo Alarm Stop Mode
0: Inertial operation stops and
remains in inertial operation state
-
0
02
All

Table of Contents

Related product manuals