69
after stopping.
2: The deceleration operation stops,
and the inertia operation state is
maintained after the stop.
30
Stopping overtime time
0.1m
s
2000
0~655
35
All
33
Motor code
-
0~655
35
All
69
Fan power on
0:Turn on the fan with temperature
greater than 45 degrees and turn off
the fan with temperature less than
42 degrees (hysteresis 3 degrees
Celsius)
1: Turn on the fan after enabling,
turn off the fan when enabling.
1
0/1
All
74
Blocking alarm time
1ms
0
0-655
35
75
Blocking alarm speed
1rpm
50
5~999
9
All
92
Low position of electronic gear
numerator
-
1
1~999
9
6
93
High position of electronic gear
numerator*10000
-
1
1~655
35
6
94
Low position of electronic gear
denominator
-
1
1~999
9
6
95
High position of electronic gear
denominator*10000
-
1
1~655
35
6