HeiTel by Xtralis ipVG Product Guide
29794_00 29
seconds after the error occurs. If the user confirms the alarm with Report again, another call will be made
6 minutes later. If the user clicks Do not report again, the transmitter will call to report the hard disk error
the next time the error is detected again with device restart.
l Select option Routine call every 24 hours, if you want to report operability of your ipVG at regular intervals
to a CamControl LITE station. No images will be transmitted during this connection. The calls will be
logged in the logfiles of the transmitter and of the receiver.
l ipVG checks all connected video signal inputs for video signal failure (faulty camera, faulty video line, low
contrast image, e.g. by covered lens). Failure is reported for active cameras if the video signal has been
disturbed for about 10 seconds. The check interval follows the respective recording interval. In the event
of a faulty video signal, recheck takes place after 3 seconds. Recording is resumed after error elimination.
For non recording video cameras failure will be reported after 60 seconds.
Note: If you require additional features, please refer to the additional configuration options in files
CAMTEL.INI or CAMCTRL.INI. Refer to the respective information in the CamControl LITE.