Appendix B: Installation Conditions for EMC Directives
63
SGDG-10GT
SGDG-15GT
Controller cable
SGDG-15GT
Noise
Filter
Controller
Clamp
Clamp
Core
Core
Core
Clamp
Motor
Encoder
CN2
CN1
PE
Power supply
AC200V
3 phase
U,V,W
L1C,L2C
Symbol Name Specification
① Shield cable (2m)
② Motor cable Shield cable (5m)
③ Encoder cable Shield cable (5m)
④ AC Line cable Shield cable (2m)
L1,L2,L3
Earth Plate/Shield Box
FG
2m
④
①
5m
③
②
Clamps : Fix and ground the cable shield using a piece of conductive metal.