■Active Mode ON Signal Allocations(∑-7W SERVOPACK with 400 V-Input Power model, using Σ-7S-compatible
I/O signal allocations)
Reverse polarity for CN1-1, CN1-2,
(Factory setting:
Polarity not
inverted)
Reverse polarity for CN1-25, CN1-26, CN1-27, and CN1-28
Note: /ACT_MOD output signal is for Axis A only.
■Active Mode ON Signal Allocations(∑-7W SERVOPACK with 400 V-Input Power model, using Multi-Axis Output
Signal Allocations)
入出力信号コネクタ(CN1) のピン番号に割り付けられる出力信号とパラメータ設定の関係を以下に示します。
Relationship between Parameter Settings and Pin Numbers (/ACT_MOD)
Disable (the signal output is not used).
Allocate the signal to CN1-1, -2.
Allocate the signal to CN1-23, -24.
Allocate the signal to CN1-25, -26.
Allocate the signal to CN1-27, -28.
Allocate the signal to CN1-29, -30.
* If Pn5BF is set to n.1□□□ (Output the signal) or n.2□□□ (Invert the signal and output it) and Pn5BF is not set to any of
these values, an A.040 alarm (Parameter Setting Error) will occur.
Relationship between Parameter Settings and Polarities (/ACT_MOD)
Disable (the signal output is not used).
Invert the signal and output it.