5.1 Wiring Main Circuit
5-5
5
(3) 750 W, Single-phase 200V
Note: Terminal L3 is not used for the single-phase 200 V, 750W SERVOPACKs. Do not connect.
Designing a Power ON Sequence
Note the following points when designing the power ON sequence.
Design the power ON sequence so that main circuit power is turned OFF when a servo alarm signal is output.
(See the circuit figure above.)
The ALM signal is output for approximately two seconds when the power is turned ON. Take this into con-
sideration when designing the power ON sequence. The ALM signal actuates the alarm detection relay 1Ry
to stop main circuit power supply to the SERVOPACK.
Select the power supply specifications for the parts in accordance with the input power supply.
SERVOPACK
SGDS-08A72A
OFF ON
(For servo
alarm
display)
Main
power
supply
Main
power
supply
L1
L1C
PG
U
V
W
M
0 V24
1Ry
ALM+
ALM
31
32
1D
1KM
1Ry
1KM
1PRT
1Ry
1KM
L2
L3
L2C
CN1
1QF
R T
1PL
FIL
+24V
A
B
C
D
B2
B3
1
2
: Indicator lamp
: Surge protector
: Flywheel diode
1PL
1PRT
1D
1QF
FIL
1KM
1Ry
: Molded-case circuit breaker
: Noise filter
: Magnetic contactor
: Relay
IMPORTANT
Power supply
Servo alarm (ALM)
output signal
2.0 s max.