5 Wiring
5.4.4 400-V Power Supply Voltage
5-18
5.4.4 400-V Power Supply Voltage
When using SERVOPACK with the three-phase 400-VAC class (380 V to 480 V), prepare the following voltage
conversion transfers (single-phase or three-phase).
When selecting a voltage conversion transfer, refer to the capacities shown in the following table.
* This is the net value at the rated load.
Fig. 5.1 Single-phase Power Supply Connection Example
• Do not connect the SERVOPACK for 100 V and 200 V directly to a voltage of 400 V.
The SERVOPACK will be destroyed.
• Control the AC power supply ON and OFF sequence at the primary side of the voltage conversion trans-
former.
Voltage conversion transformer inductance will cause a surge voltage if the power is turned ON and OFF at the second-
ary, damaging the SERVOPACK.
CAUTION
Primary Voltage Secondary Voltage
380 to 480 VAC
380 to 480 VAC
200 VAC
100 VAC
Voltage SERVOPACK Model
Voltage Capacity per
SERVOPACK * (kVA)
Current Capacity of Circuit
Breaker or Fuse (Arms)
Single-phase
100 V
SGDS-A5F
0.25 4
SGDS-01F
0.40 4
SGDS-02F
0.60 6
SGDS-04F
1.20 8
Single-phase
200 V
SGDS-A5A
0.25 4
SGDS-01A
0.40 4
SGDS-02A
0.75 4
SGDS-04A
1.2 8
SGDS-08A
2.1 16
Three-phase
200 V
SGDS-10A
2.3 7
SGDS-15A
3.2 10
SGDS-20A
4.3 13
SGDS-30A
5.9 17
Single-phase
Magnetic contactor for
power supply ON and OFF
Voltage conversion
transfer
100 or 200 VAC
SGDS
SERVOPACK
R
S
T
1KM
1KM
L1
L2
SIEPS80000025.book 18 ページ 2004年10月25日 月曜日 午前11時57分