EasyManua.ls Logo

YASKAWA SGMSS - 7.1 Trial Operation; 7.1.1 Digital Operator Operation

YASKAWA SGMSS
177 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 Operation
7.1.1 Digital Operator Operation
7-2
7.1 Trial Operation
7.1.1 Digital Operator Operation
The digital operator can be used to operate the servomotor and to perform other functions such as the multi-turn
reset.
(1) Operate with the Digital Operator
Use the digital operator to operate the servomotor with util-
ity function Fn002 (Jog Mode Operation). The factory set-
ting for jog operation is 500 min
-1
.
Check to see if the servomotor runs normally.
The operating procedure is given below.
The motor can be operated using only the digital operator. This
makes it possible to check the servomotor rotation direction and
set the speed during machine setup and trial operation without
connecting the host controller.
* When operating the servomotor with the digital operator, a
parameter can be used to change the servomotor speed, as
described below.
Parameter: Pn304, Unit: min
-1
, Standard setting: 500 min
-1
SERVOPACK
Digital
Operator
Power
Supply
SIEPS80000025.book 2 ージ 20  